HumaStar 600 System

HumaStar 600 System

  • System Specifications
  • Scope of Supply
  • Obligatory Items
  • Optional Items
banner
System Overview
  • Cat. No.: 16660
  • Analyzer type : Automatic analyzer
  • Reagent system : Closed System
  • Throughput (max. and typical) : Up to 600 tests/hr with mono reagent Typical 450 with 2 reagents (w/o ISE) Plus 120 tests/hr ISE (option)
  • Operation modes : Random Access Batch Stat (immediate access and execution)
  • Barcode reader : Built-in for sample sectors, samples and reagent
  • ISE : Optional (Na, K, Cl)
  • Reaction / reading system : Reaction cuvettes with washing station
  • Languages available : English, Spanish, Russian, Chinese Others can be translated by local distributor
  • Operating software : Window XP, Vista, Win7

Technical Specifications

Random-Access Clinical Chemistry Analyzer
Tests Measuring modes Routine chemistry, turbidimetry
Analysis modes Endpoint, kinetic, fixed time, differential, turbidimetric, bichromatic
Calculation modes Multi standard
Calculation algorithms End point, kinetic, multipoint, (linear, sigmoidal, logit4, logit5, spline)
# of programmable tests Unlimited
# of programmable profils Unlimited
# of standards per test Up to 10
Sample / Control / Calibrator Handling Sample type Serum, plasma, urine, blood, CSF
Sample vessels Sample cups or primary tubes (max. length 100 mm)
Sample positions 5 sample sectors with 19 positions each (95 sample positions)
Sampling volume 2 to 100 µl / test (in increments of 1.0 µl)
Loading Continuous
Pre-dilution Automatic predilution for calibrators, controls, blanks and samples
Post-dilution Automatic postdilution
Reagent Reagent positions 48 positions
Reagent cooling 6 ... 8° C
Reagent 1 volume range 5 to 500 µl / test each (in increments of 1 µl)
Reagent 2 volume range 5 to 500 µl / test each (in increments of 1 µl)
Reagent 3 volume range 5 to 500 µl / test each (in increments of 1 µl)
Liquid Handling Liquid transportation Pipetting arm
Liquid level sensors Frequency
Collusion detection for probe Vertical and horizontal
Clot detection Standard
Reaction Unit / Incubation Reaction wells / positions for incubation 2 x 80 cuvettes
Reaction volume (minimum) 180 µl
Reaction volume (maximum) 500 µl
Cuvette washing system 6 stage washing
Incubation temperature 37° C
Incubation time max. 10 minutes
Reading Optical system Filterwheel, continuously rotating
Readings Single or double-wavelength simultaneous reading
Light source Halogen lamp
Spectral range 340 – 800 nm
Wavelengths installed 340, 380, 405, 450, 490, 505, 550, 590, 620, 650, 700 and 750 nm
Max. # of wavelengths installed 12
Detector Silicon detector
Absorbance range (linearity) – 0.1 … 4.0 A
Data Processing Memory for Unlimited results, 360 days QC, 20 calibrations / methods
Memory capacity Depends on hard disc used
Reports for QC, calibration, blank, patient, reagent
Quality control module Levy-Jennings and Twin plots, Westgard rules
Max. number of control levels Unlimited
Test statistics Run tests, used reagent, used bottles, QC, calibration, blank
Warnings Sample related, low, high, clot, dilution, calibration range, blank range, QC range, integrity check
Printer Optional
LIS ASTM bi-directional, auto request, auto send
General PC min. requirements Processor Intel Core 2 Duo E8400 or equivalent
Memory: 1Gb Ram (Windows XP), 2 Gb Ram (Vista, 7)
Video board graphics engine GeForce 8400 or equivalent
Monitor 17'' (Vis 15.7'')
Display resolution 1024x768 or higher (vertical refresh > 70 Hz)
Color quality 16 bits or 32 bits
Hard drive 80 Gb IDE ATA 100 7200 rpm or higher
CD-RW or DVD -RW or DVD -R
Keyboard 105-key
Network adapter Ethernet 10/100 Mbits
USB 2.0 port or higher
Serial port: RS-232 serial port, additional serial port for LIS connection
Operating system: Windows XP, Windows Vista, Windows 7
Physical dimensions (WxDxH) Instrument without any components: 100 x 74 x 113 cm
Space required for routine use: 162 x 128 x 160 cm
Packaging: 135 x 86 x 135 cm
Weight: Gross: 250 kg, Net: 180 kg
Electrical requirements 110 ... 240VAC, 50/60 Hz, 2.000 VA maximum
Environmental Operating: temperature 15 ... 28° C, humidity < 80 % non condensing
Transport: temperature 15 ... 28° C, humidity < 80 % non condensing
Wash / waste tank Waste 20 liters, wash 10 liters, level sensors, external supply and drain possible